LPX3
Zone 1/21 Portables
Certification
  • ATEX Certificate Number: ExVeritas 19 ATEX 0441X

  • IECEx Certificate Number: EXV 19.0004X

Markings
  • II 2 G D

  • Ex eb mb op is IIC T4 Gb

  • Ex tb op is IIIC T80°C Db

Main Features
  • Patented optical technology
  • Long life LED
  • Easy installation, maintenance and inspection
  • Suitable for extreme conditions
  • Wide operating temperature range of -10° to +40°C
Overview

The Ex Dynamics LPX3 luminaire range is intended for use in Zone 1 and Zone 21 Hazardous areas as a handlamp. The LPX3 is suitable for hand-held usage, or suspension from the two swivel hooks located at either end of the fitting. Antistatic plastics prevent potentially dangerous electrostatic discharge in the hazardous environment.

Key Specifications

Input Voltage Range: 88 – 140 / 180 – 277 VAC

Lumen Output Up To: 2,000

Gas Temperature Class: T4

Temperature Range -10°C to + 40°C

Two sizes are available, with differing lumen outputs. The larger size has the option of being supplied with throughwiring for an inter-linkable  lighting system.

Full Specifications
LPX3.1/110 LPX3.2/110    LPX3.2-F/110 LPX3.1/230 LPX3.2/230  LPX3.2-F/230
Input Voltage Range 88 – 140 V AC 180 – 277 V AC
Input Power 16 W 24 W 16 W 24 W
Max. Input Current 0.2 A 0.35 A 0.1 A 0.15 A
Frequency 50 – 60 Hz
Power Factor > 0.85 > 0.95 > 0.85 > 0.95
Lumen Output 1200 2000 1200 2000
Weight 1.5 kg 2 kg 1.5 kg 2 kg
Ingress Protection IP66
Gas Temperature Class T4
Dust Surface Temperature T80 °C
Lower Temperature Limit – 10 °C
Upper Temperature Limit 40 °C