LHX16
Zone 1/21 High Bays
Certification
  • ATEX Certificate Number: CML 17 ATEX 3315X
  • IECEx Certificate Number: CML 17.0171X
Markings
  • II 2 G D
  • Ex eb mb op is IIC T4 Gb
  • Ex tb op is IIIC T110°C Db
Main Features
  • Patented optical technology
  • Long life LED
  • Easy installation, maintenance and inspection
  • Suitable for extreme conditions
  • Wide operating temperature range of -50° to +55°C
Overview

The Ex Dynamics LHX high bay luminaires are intended for use in Zone 1/21 Hazardous areas. Based around the Ex Dynamics floodlights, a robust, low profile marine grade LM6 aluminium housing with extensive cooling makes the LHX range suitable for the toughest environments.

Key Specifications

Input Voltage Range: 180 – 277 VAC

Lumen Output Up To: 17,900

Gas Temperature Class: T4

Temperature Range -50 to + 55

The Ex Dynamics LHX high bay luminaires are intended for use in Zone 1/21 Hazardous areas. Based around the Ex Dynamics floodlights, a robust, low profile marine grade LM6 aluminium housing with extensive cooling makes the LHX range suitable for the toughest environments.

Full Specifications
  LHX16/230 LHX16-HT/230
Input Voltage Range 180 – 277 VAC
Input Power 185 W 122.5 W
Max. Input Current 1.2 A 0.8 A
Frequency 50 – 60 Hz
Power Factor > 0.95
Enclosure Size Large
Lumen Output 17,900 12,000
LEDs 32 LED 32 LED
Beam Angles 23 °, 32 °, 71 °, 91 °
Weight 14 kg
Ingress Protection IP66
Gas Temperature Class T4
Dust Surface Temperature 110 °C
Lower Temperature Limit – 50 °C
Upper Temperature Limit 50 °C 55 °C